Fator de formulário |
QFX5100-48S: 1 U fixa de acesso/leaf QFX5100-48T: 1 U fixo de acesso/leaf
QFX5100-24Q: 1 U fixa de acesso/agregação/leaf QFX5100-24Q-AA: 1 U fixa de acesso/agregação/leaf
QFX5100-96S: Agregação de 2 U/leaf
QFX5110-48S: 1 U fixa de acesso/leaf
QFX5100-24Q: 1 U fixa de acesso/agregação/leaf
|
Dimensões (L × A × P) |
QFX5100-48S: 17,26 x 1,72 x 20,48 pol (4,37 x 44,09 x 52,02 cm) QFX5100-48T: 17,36 x 1,72 x 21,47 pol (4,37 x 44,09 x 54,54 cm)
QFX5100-24Q: 17,36 x 1,72 x 24,40 in (4,37 x 44,09 x 52,02 cm) QFX5100-24Q-AA: 17,26 x 1,72 x 20,48 pol (4,37 x 44,09 x 52,02 cm)
QFX5100-96S: 17,36 x 3,46 x 22,44 pol (8,8 x 44,09 x 57 cm)
QFX5110-48S: 17,36 x 1,72 x 24,40 pol (4,37 x 44,09 x 52,02 cm)
QFX5110-32Q: 17,26 x 1,72 x 20,48 pol (4,37 x 44,09 x 52,02 cm)
|
Capacidade de comutação |
QFX5100-48S: 1,44 Tbps/1,08 Bpps QFX5100-48T: 1,44 Tbps/1,08 Bpps
QFX5100-24Q: 2,56 Tbps/1,44 Bpps QFX5100-24Q-AA: 2.56 Tbps/1.44 Bpps QFX5100-96S: 2,56 Tbps/1,44 Bpps
QFX5110-48S: 1,76 Tbps/1,32 Bpps
QFX5110-32Q: 2,56 Tbps/1,44 Bpps
|
Densidades de porta (10/25/40/50/100/400GbE) |
QFX5100-48S: 48 x 10GbE 6 x 40 GbE
QFX5100-48T: 48 x 10GbE 6 x 40 GbE
QFX5100-24Q: 24 x 40GbE QFX5100-24Q-AA: 24 x 40GbE
QFX5100-96S: 96 x 10GbE 8 x 40GbE
QFX5110-48S: 48 x 10GbE 4 x 40/100GbE
QFX5110-32Q: 96 x 10GbE 32 x 40GbE 4 x 100GbE
|
Consumo de energia |
QFX5100-48S: 150W QFX5100-48T: 335W QFX5100-24Q: 161W QFX5100-24Q-AA: 175W QFX5100-96S: 263W
QFX5110-48S carga máxima 300W Carga típica: 195W Carga ociosa: 150W QFX5110-32Q Carga máxima: 340W Carga típica: 290W Carga ociosa: 250W
|
Capacidade de buffer |
QFX5100-48S: 12MB QFX5100-48T: 12MB QFX5100-24Q: 12MB QFX5100-24Q-AA: 12MB QFX5100-96S: 12MB QFX5110-48S: 16MB QFX5110-32Q: 16MB
|
Endereços MAC |
288,000
|
Rotas de unicast/multicast IPv4 |
QFX5100-48S, QFX5100-48T, QFX5100-24Q, QFX5100-24Q-AA, QFX5100-96S: 128.000/104.000 QFX5110-48S, QFX5110-32Q: 128.000/104.000
|
Rotas de unicast/multicast IPv6 |
QFX5100-48S, QFX5100-48T, QFX5100-24Q, QFX5100-24Q-AA, QFX5100-96S: 52.000/64.000 QFX5110-48S, QFX5110-32Q: 84.000/52.000
|
Número de VLANs |
QFX5100-48S: 4096 QFX5100-48T: 4096 QFX5100-24Q: 4091 QFX5100-24Q-AA: 4091 QFX5100-96S: 4096 QFX5110-48S: 4093 QFX5110-32Q: 4093
|
Entradas ARP |
48.000
|
latência |
550 ns
|
Gerenciamento de overlay e protocolos |
QFX5100-48S: Contrail Networking, VMware NSX L2 Gateway, VXLAN OVSDB, EVPN-VXLAN, Virtual Chassis Fabric QFX5100-48T: Contrail Networking, VMware NSX L2 Gateway, VXLAN OVSDB, EVPN-VXLAN, Virtual Chassis Fabric QFX5100-24Q: Contrail Networking, VMware NSX L2 Gateway, VXLAN OVSDB, EVPN-VXLAN, Virtual Chassis Fabric QFX5100-24Q-AA: Contrail Networking, VMware NSX L2 Gateway, VXLAN OVSDB, EVPN-VXLAN, Virtual Chassis Fabric QFX5100-96S: Contrail Networking, VMware NSX L2 Gateway, VXLAN OVSDB, EVPN-VXLAN, Virtual Chassis Fabric QFX5110-48S: Contrail Networking, VMware NSX L2 & L3 Gateway, VXLAN OVSDB, EVPN-VXLAN QFX5110-32Q: Contrail Networking, Gateway VMware NSX L2 e L3, VXLAN OVSDB, EVPN-VXLAN
|